Sunday, 26 July 2015

vmware@dmin interview questions

1)    How does VMotion works? What’s the port number used for it? 
Answer
            VMotion is used to migrate a running virtual machine from one ESX host to another host            without any down time.
vMotion:-
Live or cold migration of a virtual machine from one physical server to another server is called as vMotion.

Now come's the question, how does this happens? How is it possible? does really the user might not face an access disruption. this what the question come in the mind and here a explanation.

There are 3 underlying action happening in vMotion.

First:-
The entire state of a virtual machine is encapsulated by a set of files stored on shared storage such as Fibre Channel or iSCSI Storage Area Network (SAN) or Network Attached,Storage (NAS).

VMware vStorage VMFS allows multiple ESX® to access the same virtual machine files concurrently.

Second:-
The active memory and precise execution state of the virtual machine is rapidly transferred over a high speed network, allowing the virtual machine to instantaneously switch from running on the source ESX host to the destination ESX host.

VMotion keeps the transfer period imperceptible to users by keeping track of on-going memory transactions in a bitmap.

Once the entire memory and system state has been copied over to the target ESX host, VMotion suspends the source virtual machine, copies the bitmap to the target ESX host, and resumes the virtual machine on the target ESX host.

This entire process takes less than two seconds on a Gigabit Ethernet network.

Third:-
The networks being used by the virtual machine are also virtualized by the underlying ESX host, ensuring that even after the migration, the virtual machine network identity and network connections are preserved.

VMotion manages the virtual MAC address as part of the process. Once the destination machine is activated, VMotion pings the network router to ensure that it is aware of the new physical location of the virtual MAC address.

Since the migration of a virtual machine with VMotion preserves the precise execution state, the network identity, and the active network connections, the result is zero downtime and no disruption to users.
The port no. used for VMotion is 8000 TCP as protocol.
2)    Prerequisites for VMotion
1)    CPU compatibility (i.e., source and destination hosts should be of same family i.e., Intel or AMD).
2)    Storage should be common or shared storage.
3)    Resources should be available on the destination host.
4)    Physical network should be same network.
5)    Create vmkernel port group in both source and destination hosts.
6)    No access of mountable devices.
7)    No permission of vmx file.

3)    Prerequisites for HA?
1)     CPU compatibility (i.e., source and destination hosts should be of same family i.e., Intel or AMD).
2)    Storage should be common or shared storage.
3)    Resources should be available on the destination host.
4)    Physical network should be same network.
5)    Create vmkernel port group in both source and destination hosts.
6)    Host should be configured with FQDN.
7)    DNS should be configured with Host name.

4)    How do DRS works? Which technology used? What are the priority counts to migrate the VM’s?
DRS means Distributed Resource Scheduler. Its main function is Load Balancing Mechanism. VMware DRS allows users to define the rules and policies that decide how virtual machines share resources and how these resources are prioritized among multiple virtual machines.
When a virtual machine experiences increased load, VMware DRS first evaluates its priority against the established resource allocation rules and policies, and if justified, allocates additional resources. Resources are allocated to the virtual machine by either migrating it to another server with more available resources or by making more “space” for it on the same server by migrating other virtual machines to different servers. The live migration of virtual machines to different physical servers is executed completely transparent to end-users through VMware VMotion™.
VMware DRS uses VMware VMotion technology to automatically and transparently move running workloads between systems to provide a level of runtime flexibility unique to virtual environments.
For each migration recommendation, the priority level is limited to the integer range priority 2 to priority 5 (inclusive).
For each migration recommendation, the priority level is limited to the integer range priority 2 to priority 5             (inclusive). It is calculated according to this formula:
6 - ceiling(LoadImbalanceMetric / 0.1 * sqrt(NumberOfHostsInCluster))
Here, ceiling (x) is the smallest integer value not less than x. LoadImbalanceMetric is the current host load standard deviation shown on the cluster's Summary page of the vSphere Client.
      For each host:
  1. Compute the load on the host as

    sum(expected VM loads) / (capacity of host)

    This value is the host load metric.
  2. Compute the standard deviation of the host load metric across all hosts to determine Load balance Metric.
These formulas apply only to ESX/ESXi 4.x and VCenter Server 4.x. They are subject to change.

5)    How does snap shot’s works?
Snapshot is a pre-reserved state of a virtual machine.
 A VMware snapshot is a copy of the virtual machine's disk file (VMDK) at a given point in time.
6)    What are the files will be created while creating a VM and after powering on the VM?

The default files created while the VM is created are
VMX file – Configuration
VMXF file – Supplementational Configuration
VMDK Files – Disk related files, includes .VMDK, -delta.vmdk, -rdm.vmds
VSWP File – Memory overflow (SWAP) file
VMSD File – Snapshot details
VMSS File – Memory contents of suspended VM
VMSN File – Snapshot Files
NVRAM File – BIOS file
Log files
           After powering on the VM
           VSWP file
 At VM power on,  a memory swap file is created, it is equal to the memory designated to the VM in its VM settings.  If the ESXi host cannot provide sufficient memory to the VM, and Ballooning cannot be utilized to free memory then the host will use this file as memory overflow.
7)    If the VMDK header file corrupt what will happen? How do you troubleshoot?
If VMDK header corrupted following will happen
·         Failed to open disk.
·         The file specified is not a virtual disk (15) 3023.
·         Cannot open the disk or one of the snapshot disks it depends on.
·         The file specified is not a virtual disk
To resolve this issue, you have to recreate the VMDK header/descriptor file.
 If the virtual machine is using persistent disks, see Recreating a missing virtual disk (VMDK) header/descriptor file (1002511). 
On products such as VMware Workstation and VMware Server, you need to use the vmware-vdiskmanager utility to create a new disk of the same type and size of the -flat.vmdk file.
In Windows, this utility is located in the install directory of VMware Server or VMware Workstation (C:/Program Files/VMware/).
 To recreate the VMDK header/descriptor file:
If you are using Windows, locate the utility in the install directory of VMware Server or VMware Workstation (C:/Program Files/VMware/).
Run the command:
vmware-vdiskmanager.exe <create disk> <size> <adapter> <disk-type> <path>
For example, to create a 20 GB persistent size disk for use with Windows Server 2003 on the e: drive, run the command:
vmware-vdiskmanager.exe -c -s 20GB -a lsilogic -t 2 "e:\newdisk.vmdk"
Note: For more information about vmware-vdiskmanager.exe, consult the Linux man page (man vmware-vdiskmanager) or Windows Help (vmware-vdiskmanager /?).
 Copy the new VMDK descriptor file to the folder where the problematic virtual machine is located, and edit the flat file to which it points so it has the correct name.
8)    What are the prerequisites for installing VC and Update manager?
Hardware requirement for installing VC and update manager for ESXi 5.x 
Hardware Requirement
Processor: Intel or AMD x86 processor with two or more logical cores, each with a speed of at least 2GHz
Memory:2GB RAM if Update Manager and vCenter Server are on different machines
4GB RAM if Update Manager and vCenter Server are on the same machine
Networking:10/100 Mbps
Note: For best performance, use a Gigabit connection between vCenter Update Manager and the ESX/ESXi hosts
vCenter Update Manager 5.x requires a 64-bit operating system and cannot be installed on a 32-bit operating system. When performing an install you must ensure that your operating system is 64-bit capable
update manager requires 32-bit DSN to communicate with database and it requires min 120GB storage space to store patches
9) I turned on Maintenance mode in an ESX host, all the VM’s has been migrated to another host, but only one VM failed to migrate? What are the possible reasons?
1. Is the VM in the same shared datastore as the other VMs.
2. Is the other host resource setting preventing the vm to be migrated.
3. Post the last set of vmkernel logs to know more about the failure.
4. Is by any chance, any additional disks are configured as RDM.
10) How will you turn start / stop a VM through command prompt?
    There may be times when you can't manage ESX through the GUI, but thankfully you can still manage virtualization from the command prompt.
First, you can list all the VMs on a server using the vmware-cmd -l command. For example,
vmware-cmd -l
Produces
/vmfs/volumes/f27f61fa-1c0f60ae/Test/Test.vmx
/vmfs/volumes/f27f61fa-1c0f60ae/savdalvdi01/savdalvdi01.vmx
/vmfs/volumes/f27f61fa-1c0f60ae/savdalesxvc/savdalesxvc.vmx
/vmfs/volumes/f27f61fa-1c0f60ae/savdalappv01/savdalappv01
.vmx
Note that you're shown the VMX location for each VMs. You need these paths to actually control the VMs.
To check if a VM is running, specify the VMX file and the getstate switch. For example,
vmware-cmd /vmfs/volumes/f27f61fa-1c0f60ae/savdalesxvc/
savdalesxvc.vmx getstate
returns
getstate() = off
To start a VM, just use the start switch. For example,
vmware-cmd /vmfs/volumes/f27f61fa-1c0f60ae/savdalesxvc/
savdalesxvc.vmx start
returns
start() = 1
The VM will now be running.
11)  I have upgraded a VM from 4 to 8 GB RAM; it’s getting failed at 90% of powering on? How do you troubleshoot?
12) Storage team provided the new LUN ID to you? How will you configure the LUN in VC? What      would be the block size (say for 500 GB volume size)?
13)  I want to add a new VLAN to the production network? What are the steps involved in that? And how do you enable it?
14)  What’s the difference between Top and ESXTOP command?
            Difference between TOP and ESXTOP commands:-
1.    Vmware ESXTOP command is used to for Storage Monitoring.
2.    ESX TOP show the service console performance (or) ESX host performance.
3.    Monitors overall storage performance per HBA.
4.    Monitors storage performance per LUN.
5.    Monitors storage performance per VM.
6.    TOP command is used to shows how many users are logged in to virtual center.
15)  How will you check the network bandwidth utilization in an ESXS host through command prompt?
            
 16) How will you generate a report for list of ESX, VM’s, RAM and CPU used in your Vsphere environment?
Two ways to generate report for ESXi,VM,RAM and CPU
A)   use the vCenter performance charts, select chart options and chose the the resource & corresponding metrics
B)   Go to host>click File>Report>host summary(or)performance

17) What the difference between connecting the ESX host through VC and Vsphere? What are the services involved in that? What are the port numbers’used?
The ports used for connecting ESX host through vsphere  is HTTP port 80 and HTTP port 443
18) Can I deploy a VM by template in different data centres?
Yes we can deploy vm by template in different data centers.
Procedure to deploy VM from template
Right click on template>select deploy a virtual machine
Start deploy a virtual machine from a template task
>Select virtual machine name and folder>Select resource>Select a data store
19)  I want to increase the system partition size (windows 2003 server- Guest OS) of a VM? How will you do it without any interruption to the end user?
Through Extpart.exe we can increase the partition size (C:\) without any interruption to the end user. Remaining partitions we can increase through diskpart.

20)  Which port number used while 2 ESX transfer the data in between?
       
21)  Unable to connect to a VC through Vsphere client? What could be the reason? How do you troubleshoot?

                    Cause

This issue occurs if there is a proxy server between the vSphere Client and vCenter Server. The vSphere Client does not support proxy connections to connect to vCenter Server.

Resolution

To resolve this issue, disable the connection to the proxy server.

To disable the connection to the proxy server:
  1. Click Start Control Panel.
  2. Click Network and Sharing Center or Network and Internet.
  3. Click Internet Options in the left pane.
  4. Click the Connections tab.
  5. Click LAN Settings.
  6. Deselect Use a proxy server for your LAN.
  7. Click OK.
  8. Click OK to close the Internet Properties window.
22)   Have you ever upgraded the ESX 3.5 to 4.0? How did you do it?
        Yes.
        Steps:-
1.    Login to client environment.
2.    Open internet explorer and enter ILO IP. It will login into physical server.
3.    Click on resource console at the left pane.
4.    Click on launch java at right pane. Console will be opned.
5.    Click on ADD Virtal Disk. And select the ISO image of ESX 4.0.
6.    Click on power source. And select Cold Boot.
7.    Rebooting will start with in server.
8.    In between upgrading It will ask for Storage option then we will give server storage i.e., HP\DELL.
9.    Select ESXI overwrite on data store.
10.  Reboot is completed. After this provide IP to the server.

23)  What is AAM? Where is it used? How do you start or stop through command prompt?
 AAM is the Legato automated availability management.  Prior to vSphere 4.1,    VMware’s HA is actually re engineered to work with VM’s with the help of  Legato’s Automated Availability Manager (AAM) software. VMware’s vCenter agent (vpxa) interfaces with the VMware HA agent which acts as an intermediary to the AAM software. From vSphere 5.0, it uses an agent called “FDM”  (Fault Domain Manager).Upto ESXi 4.1 ‘AAM’ was used as HA agent
service vmware-aam restart
service vmware-aam stop
service vmware-aam start

24)  How will you change the service console IP?
25)  What’s the difference between ESX and ESXi?
         Diff. Btw ESX and ESXi:-
1.    ESX supports service console (CLI) command line interface whereas ESXi does not support service console.
2.    ESX supports CLI and GUI whereas ESXi supports only GUI
3.    ESX supports virtual apps and scripting whereas ESXi also supports virtual apps and scripting after the introduction of Power CLI from ESXi 5.0.
4.    ESX versions:- 2.5, 3.0, 3.5, 4.0
ESXi versions:- 3.5, 4.0, 4.1, 5.0, 5.1, 5.5.

26)  What is the Maximum Virtual SCSI adapters per virtual machine?
27)  What is the Maximum Virtual SCSI targets per virtual SCSI adapter?
28)  What is the Maximum IDE controllers per virtual machine?
29)  What is the Maximum Parallel ports per virtual machine?

Answers for Q. no’s 26, 27, 28, 29 are tabulated below.
ESXi versions
Max. Virtual SCSI adapters per VM
Max. Virtual SCSI targets per virtual SCSI adapters
Max. IDE controllers per VM
Max. Parallel ports per VM
4.0
42
153
15
3
4.1
41
152
13
3
5.0
42
153
14
3
5.1
4
152
13
3
5.5
4
152
13
3





Conversions sometimes fail no matter how careful you are preparing the server. The failure can occur at various stages in the conversion process; these stages are based on the task bar percent and are estimated values.
1.      Creation of the target virtual machine (VM) (0%-5%)
2.      Preparing to Clone the Disk (5%-6%)
3.      Cloning (6%-95%)
4.      Post-cloning (95%-97%)
5.      Customization/Reconfig (97%-99%)
6.      Install Tools/Power On (99%-100%)
The conversion process may fail at any stage, but if it’s going to fail, it will typically fail at 97%. Converter creates a detailed log file during the conversion process which will contain exact errors pertaining to why the conversion failed.
This log file is located on the server you are converting that is running the Converter agent, and is usually named vmware-converter-0.log and is located in the C:\Windows\temp\vmware-temp directory. Open this log file and scroll towards the bottom and look for failure errors. Once the process fails, Converter will destroy the VM that it created automatically.
One clue to determine which stage it failed at is how fast it gets to 97%. If it jumps to 97% quickly and fails, this usually indicates a problem with network ports, DNS resolution or a required Windows service that is not running. Here are some things to try to resolve these types of problems.
1.      If you used a hostname to choose your VC/ESX server destination make sure you can resolve it on your source server. Also try using the FQDN of the server instead of the short name.
2. On the source server make sure the Workstation, Server, TCP/IP NetBIOS Helper and VMware Converter services are running. On Windows XP and 2003 servers make sure the Volume Shadow Copy service is not disabled, by default it should be set to Manual. This service does not need to be running for Converter to work.
3. Use telnet to see if you can connect to the required ports on the VC/ESX servers. From the source server type “telnet 902″. You should get a response back from the VC/ESX server, also do this on port 443.
4. Try rebooting the source server, this is a requirement for Windows NT and 2000 servers.
If it takes a long time to get to 97%, then typically the clone failed during the data cloning process or the post-cloning procedures. Some possible causes of these types of failures can be lost network connectivity between the servers, excessive network errors and source disk problems. Here are some steps to try to resolve these types of problems.
1.  Verify network speed/duplex settings match on your source server’s NIC and the physical switch port it is connected to.
2.  If you have OS mirroring enabled, break the mirrors.
3.      Clean-up your boot.ini file and make sure it is correct.
4.      Make sure you are using the latest version of Converter. Earlier versions fail if the source server has dynamic disks.
5.      Run chkdsk on your source server to verify file system integrity.
6.      Ensure you have at least 200 MB of free disk on the source server.
7.      If your source server has more then two serial (COM) ports, edit the registry and look for HKLM\HARDWARE\DEVICEMAP\SERIALCOM and remove any ports above serial port 2. You can export the key before you do this and re-import after the conversion is completed if needed.
Finally, if your conversion completes successfully but your server will not boot (or boots to a blue screen) you can try the following things to fix it.
1. Edit the boot.ini on the newly created VM to make sure the disks are in the proper order. Sometimes the boot disk will not be listed as the first partition. To do this, simply use a working VM as a helper and add an additional virtual hard disk. Browse to the newly created VM’s disk file.
You can then browse that disk and edit the boot.ini file. When complete, remove the disk from the helper VM. You can also try running Converter again and selecting “Configure Machine” and select your newly created VM. Run through the Wizard, and (when complete) try powering it on again.
2.  Verify you are using the proper SCSI controller for your virtual disk (BusLogic or LSI Logic).
3.  Boot the VM in safe mode to see if any hardware specific services/drivers are loading.
Enhancing performance in a new virtual machine
When your conversion completes, there are several steps you should to do clean your new VM up so it will perform better.
1. Edit the VM’s hardware. Remove all unnecessary hardware, including floppy drives and serial, parallel and USB ports. You should only give the VM as much RAM as it needs. Reduce it if you can. Most VM’s run better with one vCPU, so consider reducing the number of CPUs if you came from a SMP physical server.
2. Power on the VM, wait a few minutes to let it discover all it’s new hardware then reboot it.
3. Check the server HAL, if you came from a multiple CPU physical system and have a single CPU VM you need to go into Device Manager and edit the CPU (Computer). Select Update Driver, say No to Windows Update, select Install from List, select Don’t Search and select ACPI Uniprocessor instead of ACPI Multiprocessor.
4.      Remove any hardware specific applications and drivers.
5.      Finally, my most important tip: Remove all non-present hardware devices. These are hardware devices that were removed from the system without having been uninstalled and are a by-product of the conversion.
These devices are not physically present in the system any more, but Windows treats them as they were there and devotes system resources to them. They can also cause conflicts when trying to set your new network adapter’s IP address to the same address of the source server. The reason for this is that the old NIC still exists as non-present hardware with an IP address. There will be dozens of non-present hardware devices left after the conversion.
To remove them all simply go to a CMD prompt and type SET DEVMGR_SHOW_NONPRESENT_DEVICES=1.
Then in the same CMD window type DEVMGMT.MSC and then select Show Hidden Devices when the Device Manager window opens.
As you expand each hardware category you will see lots of non-present devices, indicated by grayed out icons. Right-click on each and select uninstall. Reboot once you have removed them all.